  • Separation efficiency: Close to 100%, depending on version and application.
  • Blow-by gas rate: 50-600 lit/min, depending on version.
  • Temperature range: -40°C to +125°C, peak +140°C up to 5% of service life. Can be positioned close to hot components (i.e. turbocharger, etc).
  • Internal pressure drop: None (instead there is small controlled suction extracting gases from the crankcase).
  • Pressure control: An internal pressure control valve makes sure that the crankcase pressure is kept within specified range.
  • Service life: Designed for a service life L10 of 1,600,000 km or 20,000 hours, whichever comes first. 